Minimum Order Quantity | 01 Set |
Max Water Recovery Rate | >75 % |
Number of Filtration Passes | >5 |
Number of Membranes in RO | 4 |
RO Capacity | 1000 Liter/hr - 20000 Liter/hr) |
Plant Application | Industrial RO Plant |
Automatic Grade | BOTH |
Superior Grade Stainless Steel 304 And 316 For Pharmaceutical Industrial And Institutional Use | BOTH |
Installation Service | Yes |
Condition | New |
Control Panel | With Control Panel |
High pressure pump | GRUNDFOS |
Voltage | 415 V |
Power Consumption | 4 KW |
Frequency | 50 HZ |
Operation Mode | MANUAL - AUTO |
Mounting Type | SKID |
Filter Cartridges | YES |
Warranty | 1 YEAR |
Certification | CE |
Phase | 3 |
Source of Water | ANY |
Manufacturing Lead Time | 30 - 120 DAYS |
Working Temp. | Max. 40 C |
Type Of Machines | RO |
Purification Type | SEPARATION TECHNOLOGY |
Bottle Filling Capacity | 50 Bottle/min |
Certifications | BIS |
Purification Capacity | 1000 Liter/hr - 20000 Liter/hr |
Water Filling Method | Bottle Filling |
Automation Grade | Semi-Automatic |
Material of Construction | Stainless Steel |
Min Order Quantity | 01 |
Frontal Pipeline | SS 304 |
Features | LOWER POWER CONSUMPTION |
Usage/Application | Mineral Water |
Capacity | 1000 Liter/hr - 20000 Liter/hr) |
Ro Membrane | DOW / HYDRANAUTICS |
Input Tds | 3000 - 15000 |
Water Source | all |
Drinking Water Plant
• RAW WATER STORAGE TANK (RWST) (BY CLIENT)
• RAW WATER PUMP (RWP)
The Raw Water would be pumped to the MGF, MCF and R.O. Module by means of Raw Water Pump. This pump will create minimum head required for the Multi Grade Filter pump to boost the water.
• MULTIGRADE SAND FILTER (MGF)
The raw water from its source will be directly passed through the MGF to remove suspended solids from the same. The Multi grade Sand filter will be designed for a filtration velocity of 19 -20 m/hr for efficient filtration.
• ACTIVATED CARBON FILTER (MGF)
The raw water from its source will be directly passed through the ACF to remove Chlorine, Color & Odor from Raw water. The Charcoal Filter will be designed for a filtration velocity of 19 - 20 m/hr for efficient filtration.
• ANTISCALENT DOSING SYSTEM
It is proposed to dose Special Food Grade Antiscalent in the feed prior to the cartridge filter for RO system to prevent saturation of various organic salts especially Silica on RO membrane surface on concentration.
The features of this Antiscalent are:
ü Prevent organic and inorganic fouling of the Reverse Osmosis system.
ü Take care of high incoming silica and bicarbonate load in the feed to the RO thus Reducing Scaling of the RO Pressure Tubes.
• MICRON CARTRIDGE FILTER (MCF)
A MCF is provided to remove fine suspended solids, which may escape from upstream units. 5 Micron cartridge filter is provided which will remove fine suspended solids up to 5 micron, which if not trapped may clog the RO membrane. This would also eliminate problems in the high-pressure pumps due to presence of particulate matter.
• CHEMICALLY SANITISABLE REVERSE OSMOSIS SYSTEM (CSRO)
CSRO will serve the purpose of Reducing TDS 800 to around < 50 ppm.
The RO unit shall have a conductivity meter at the outlet to monitor the performance.
• pH CORRECTION SYSTEM
There is the provision for pH Correction Dosing System to maintain the pH of RO Product Water. It will give an additional sweet taste in RO Product Water.
• RO WATER STORAGE TANK (ROWST)
• RO WATER TRANSFER PUMP
The RO Water would be pumped to the Post Micron Cartridge Filter & UV System by means of RO Water Transfer Pump.
• ULTRAVIOLET STERILISATION SYSTEM
UV sterilizers utilize UV germicidal lamps which emit UV-C wavelength at 253.7nm lethal to bacteria, viruses and other microorganisms present in the water. Ultraviolet technology has been one of the most effective methods of water treatment and air purification, without using any chemicals.
• ENDOTOXIN CARTRIDGE FILTER (ECF)
A ECF is known as finest polishing system. It is provided to remove fine suspended solids, which may escape from upstream units. 1 Micron & 0.2 Micron Cartridge Filter is provided which will remove fine suspended solids up to 0.2 micron, which if not trapped may ruin the RO Product Water.
• FINAL PRODUCT WATER STORAGE TANK (PWST)
• OZONATOR
Oxygen (O2) will convert into Ozone (O3) by Ozonator. Ozone destroys all the water-borne pathogens and also helps reducing some of the organics present in the water. Besides purifying the water, it is essential to maintain some amount of residual ozone in water before packaging. This helps in sterilizing the bottles or the jars in which the water is being packaged.
Minimum Order Quantity1 SetWater Purification ProcessROWater Filling MethodBottle FillingPlant Accessori... Continue
Minimum Order Quantity01 SetWater SourceBorewell Water, Municipal Water Supply, River Water, Open Well water... Continue
Minimum Order Quantity01 SetAutomation GradeSemi-AutomaticPower Supply415 VWater SourceALLApplicable... Continue
Minimum Order Quantity1 NumberCapacity4000 - 6000 Bottles/hrDriven TypeElectricVoltage415 VPower Con... Continue